Skimmer Pump Maintenance
Recommended Skimmer
Pump Maintenance Interval
With Calcium Reactor,
Kalkwasser Reactor and/or 2-Part Dosing: every 3 to 4 months
With Deltec Fluidized
Calcium Reactor: every 1 to 2 months
Without any of the
above: every 6 to 9 months
Recommended
Cleaning Media
Distilled White Vinegar (this is what we use)
Muriatic Acid
EZeClean
1. Remove skimmer pump from skimmer
2. Remove impeller and shaft from the pump
3. Soak just the impeller and shaft separately in a small bowl
of 100% vinegar
for about an hour. Do not put anything else in the bowl of
vinegar, especially rubber parts, so just the impeller and shaft
4. At the same time, place the pump in a 5 gal bucket with about 20% warm vinegar solution for about
an hour. Warm tap water is fine to mix with the distilled
white vinegar
5. After an hour, clean the center of the impeller where the
shaft inserts into by running a small pump brush or pipe cleaner
through the center of the impeller
6. Pour the bowl of vinegar into the bucket, reassemble the
pump and run the pump in the bucket for about an hour
7. After an hour, use a larger brush to clean inside the impeller chamber, volute &
pump cover, and the pump's outlet. Use the small pump brush or
pipe cleaner and clean out the nipple where the air hose connects to
the volute
8. Rinse everything in warm water before reassembling, you're
done!
We also recommend that you completely clean your entire skimmer once
a year in 20% warm vinegar solution, just like the cleaning you did
before you first installed your new skimmer. |